Milk system cleaner mini tabs, 90 g refill
Ninety-gram refill for about 30 milk-system cleaning cycles, made to remove milk fats and proteins from the tubes.
- Compatibility regions
- FR, EU
- Compatibility source
- JURA · 27 August 2026

Your appliance
For JURA E8 Cosmic Black ED, this catalogue documents 1 part or accessory in Care products. Check the exact reference 24157 and its manufacturer evidence before ordering.
Documented matches for this model
Confirmed parts for JURA E8 Cosmic Black ED: 24157. Each match keeps its model details, applicable regions and source.
Buying options appear beside the matching part when they are available.

Ninety-gram refill for about 30 milk-system cleaning cycles, made to remove milk fats and proteins from the tubes.
Verified compatibility
JURA recommends its milk-system cleaner mini tabs for E8 15749 and identifies refill 24157 as the 90 g format.
JURA — View at the manufacturer · source in FrenchLast checked: 27 August 2026Availability and references can vary by country. Compare the complete reference before ordering.

Thin or irregular E8 foam points first to the fine-foam frother, its air intake and milk-system hygiene, not to the coffee grinder.
Start diagnosis
An E8 that dispenses coffee only in drops usually needs a coarser grinder setting or the documented coffee-system cleaning cycle.
Start diagnosis
A full E8 tank with the Fill water tank message usually means the internal float is trapped rather than a low-water condition.
Start diagnosis
A suddenly loud E8 grinder can mean a foreign object is inside; continuing to grind risks damaging the burrs.
Start diagnosis
Error 2 or 5 can appear when an E8 has been exposed to cold and heating is temporarily disabled for safety.
Start diagnosis
E8 Cosmic Black ED: The E8 has counted used portions or detected a full tray; the two removable containers must be emptied while the machine can register the action. With the E8 switched on, pull out the complete drip-tray assembly, empty grounds and liquid, rinse and dry the metal contacts, then refit the assembly without… Preserve the exact words, code, timing and drink before changing anything: a similar symptom can have a different cause.
Start diagnosis
E8 Cosmic Black ED: The E8 does not detect the complete drip-tray assembly; this is separate from a tray-full message. Check that the grounds container sits correctly on the tray, dry the rear contacts and slide the complete assembly straight in until flush; do not bridge the contacts.
Start diagnosis
E8 Cosmic Black ED: The grinder has no beans available; this message is not the same as the existing full-hopper false detection paths on other brands. Remove any aroma cover, add dry untreated coffee beans only and close the cover.
Start diagnosis
E8 Cosmic Black ED: The thermoblock is temporarily above the temperature allowed for the selected maintenance programme, not necessarily overheated in normal use. Wait for the E8 to cool or prepare the drink or hot-water operation suggested by the manual, then start maintenance again; do not cool it with added ice or water… Preserve the exact words, code, timing and drink before changing anything: a similar symptom can have a different cause.
Start diagnosis
E8 Cosmic Black ED: The CLARIS Smart+ filter capacity is exhausted and the E8 is asking for the guided replacement sequence. Remove the tank, replace the filter with the specified CLARIS Smart+ cartridge, refill with cold fresh water and follow the Filter programme until its rinse ends.
Start diagnosis
E8 Cosmic Black ED: The E8 has reached its coffee-system cleaning counter; rinsing the tray does not remove coffee oils from the guided path. Start Cleaning from the maintenance menu, use one JURA cleaning tablet only when the display requests it and let every rinse complete with the tray and container in place.
Start diagnosis
E8 Cosmic Black ED: The E8 is configured without an active filter or has reached its scale counter; cleaning tablets do not descale the water circuit. Start Descaling from maintenance, dissolve the specified JURA tablets in the stated water volume and complete both descaling and fresh-water phases without interruption.
Start diagnosis
E8 Cosmic Black ED: Milk residue remains in the fine-foam path after use; a water-only rinse is not the documented hygiene programme. Use the JURA milk-system container and cleaner in the maintenance programme, connect the milk pipe as shown and let both cleaning and water-rinse stages finish.
Start diagnosis
E8 Cosmic Black ED: The bypass chute received too little ground coffee for the selected preparation; it does not mean the bean hopper is empty. Acknowledge the cancelled drink, keep the chute dry and for the next bypass drink add one level measuring spoon within the manual’s stated range before selecting the drink.
Start diagnosis
E8 Cosmic Black ED: Coffee strength or grind setting can make loose dry grounds miss the container; this differs from liquid leaking under the machine. Clean the dry accessible compartment with the machine off, reduce coffee strength or choose one finer grinder step only while the grinder runs, then compare two identical drinks.
Start diagnosis
E8 Cosmic Black ED: A milk or limescale blockage in the fine-foam frother connector can restrict flow while the pump stays unusually quiet. Let parts cool, remove the fine-foam frother and use the supplied spoon’s hex opening to unscrew the black connector; clean and refit only those removable pieces exactly as shown.
Start diagnosis
E8 Cosmic Black ED: The E8 manual reserves other Error messages for JURA support; the number must be preserved rather than converted into a guessed part. Photograph the complete Error number, switch off with the On/Off button, unplug once and contact JURA if it returns; do not remove covers or repeatedly restart it.
Start diagnosis